- Model
- TJ-EFN3002
- Display
- Digital
- Weight
- 100-500Kg
- Channels
- 2 Channels
- Frequency Range
- 10 Hz - 12 MHz
- Excitation Mode
- Dp/Di
- Specification
- 50*50*30cm
- Power Supply
- AC 220V/110V
Detailed technical parameters
Transcribed from the matching manufacturer's Made-in-China product description. Series-level values, options and configurations require confirmation before ordering.
- Detection channel
- 2 (multi-channel can be expanded)
- Frequency range:
- 10 Hz ~12 MHz, continuously adjustable;
- Gain range
- 0.0 ~99.0 dB continuously adjustable, step: 0.1
- Gain ratio
- (X/Y) 0.1~10.0; continuously adjustable, can be fine-tuned, quickly increased/decreased
- Signal-to-noise ratio
- ≥10dB, up to 30db, (depending on the detection conditions and detection standards)
- Missed judgment rate
- ≤0%, misjudgment rate (misjudged qualified products as unqualified products) ≤3% (depending on the test conditions and test standards)
- Stability
- 16 hours <=2dB
- Phase rotation
- 0 ~360° continuously adjustable, step: 1;
- Adjustable probe drive (excitation) level
- 1~16
- Hardware amplification factor
- 1dB~32dB continuously adjustable, step: 1dB;
- Multiple excitation modes
- DP/DI; can be configured with differential, absolute and various customized special probes.
- Function
- With end and end signal removal function
- Adjustable alarm duration
- 10ms~60000ms, step 1ms;
- marking accuracy
- ≤±10mm (requires external support, depending on the detection speed and requirements
- Multiple display modes
- Impedance, time base, A\B scan, 8-frequency sorting, analog 3D display (optional depending on the model);
- Real-time software/hardware output alarm
- Real-time software/hardware output alarm, multiple alarm window modes (circular, square, fan-shaped, customized), support yellow, orange and red three-level alarm functions, with first-level pre-alarm, second-level alarm, third-level alarm and other functions, and can realize the output of three independent alarm, spraying and sorting signals;
- Power supply
- AC 220V/110V
- Working temperature
- 0 ºC~+45ºC
- Storage temperature
- -20 ºC~+50ºC
- Relative humidit
- ≤85%;
- Blanking display coefficient
- 1~400
- Digital filtering:
- Filter coefficient: 0-30000; Digital filtering: low pass (0Hz~2000Hz) high pass (0Hz~2000Hz); Adopt unique "digital filtering" to effectively suppress on-site interference signals and ensure the accuracy and stability of detection
ORIGINAL PRODUCT DETAIL IMAGES
TJ-EFN3002 product details and inspection illustrations
Technical illustrations from the supplier's matching product description. The final scope of supply and optional functions should be confirmed with TAIJIN.
Discuss your inspection application
Tell us the tube or component material, diameter or dimensions, defect type, inspection speed and probe requirements. We will confirm a suitable system configuration.
Request TJ-EFN3002 Quotation →