SHENZHEN TAIJIN PRECISION INSTRUMENT CO., LTD.Testing · Measurement · Inquiry
TJTAIJINPRECISION INSTRUMENTS

TAIJIN / EDDY CURRENT TESTING

EM300 Multi-Channel Eddy Current Flaw Detector

Multi-channel eddy current inspection equipment for metal components and automated inspection applications.

PRODUCT OVERVIEW

Multi-Channel Eddy Current Flaw Detector

Multi-channel eddy current inspection equipment for metal components and automated inspection applications.

Model: EM300

Equipment type: Online / Automated

Product photos are sourced from the matching model listing. Available functions, optional probes, and the exact supplied configuration should be confirmed before ordering.

Request a Quote →

Please specify model EM300 in the inquiry requirements.

MODEL INFORMATION

EM300 — stated specifications

The values below are taken from one listing with this exact model number. Listings for the same model may describe different configurations; confirm details with TAIJIN.

Model
EM300
Accuracy Grade
0.5
Display
a/B Scan
Weight
2.5kg
Channels
1-8 Physical Channels/1-8 Signal Channels
Frequency Range
5 Hz ~ 12MHz
Power Supply
AC 220V/110V
Gain Range
0.0dB~99.0 dB Continuously Adjustable
Excitation Mode
Dp/Di
Specification
350*330*120mm (L * W * H)

Detailed technical parameters

Transcribed from the matching manufacturer's Made-in-China product description. Series-level values, options and configurations require confirmation before ordering.

Channel
1-8 physical channels/1-8 signal channels
Detection function
metal surface and near surface defect detection, hardness sorting (optional), can be displayed on the same screen
Frequency range
5Hz ~12MHz, continuously adjustable
Gain range
0.0dB ~99.0dB continuously adjustable, step: 0.1dB; can be fine-tuned, quickly increase/decrease;
Gain ratio
(X/Y) 0.1 ~10.0; continuously adjustable, fine-tuning, fast increase/decrease;
SNR
≥10dB (up to30db);
Phase rotation
0 ~360° continuously adjustable,
Adjustable probe drive (excitation) level
1 ~16 level;
Filter coefficient
0-10000
the maximum measurement value
10 ~10000
Hardware amplification factor
1dB ~39.9dB continuously adjustable
Multiple excitation modes
DP/DI; Differential,absolute and various customized special probes can be configured.
probe abnormal alarm function
option
Digital filtering
low-pass (0Hz ~2000Hz) and high-pass (0Hz~2000Hz); unique "digital filtering" is adopted to effectively suppress on-site
Stability
16 hours <=2dB;
Multiple display modes
impedance,time base, A\B sweep, 8-frequency sorting, analog 3D display (optional depending on model);
Signal display mode:
It has the ability to select standard display mode, custom signal display setting mode, multiple alarm window modes (circular, square, fan-shaped, customized, non equal amplitude, asymmetric phase alarm area settings;), and has a three-level alarm function
Alarm trigger display
Optional display, trigger display, and no display
Alarm duration
10ms~60000 ms, in steps of 1 ms, adjustable
Signal output
real-time and delayed software/hardware alarm output
Detection range
maximum measurement value: 10-10000, adjustable in steps of 1
operating languages
Chinese and English
Working environment power supply
AC 220V/110V
Working temperature:
-10 ºC~+45ºC,
Working temperature
0 ºC~+45ºC
storage temperature
-20 ºC~+50ºC
relative humidity
≤85%
User management function
more user-friendly parameter setting permission management and software authorization management.;

ORIGINAL PRODUCT DETAIL IMAGES

EM300 product details and inspection illustrations

Technical illustrations from the supplier's matching product description. The final scope of supply and optional functions should be confirmed with TAIJIN.

Discuss your inspection application

Tell us the tube or component material, diameter or dimensions, defect type, inspection speed and probe requirements. We will confirm a suitable system configuration.

Request EM300 Quotation →